Questions, bugs, or ideas — we're happy to help.
Phon runs on any iPhone with iOS 17 or later. External microphones must be USB-C measurement microphones, so they need an iPhone 15 or later. Phon is built and tested with the Dayton Audio iMM-6C.
With the built-in microphone, readings are approximate. Phon applies a per-model offset so the number is meaningful, but iPhone microphones are not measurement microphones and the readout says APPROX. for that reason. A calibrated USB-C measurement microphone with its calibration file loaded is much closer. Phon is not a certified Class 1 or Class 2 instrument and must not be used where one is legally required.
Plug the microphone into the USB-C port. A banner reading EXTERNAL MIC DETECTED · TAP TO USE appears at the top; tap it and the header shows the microphone's name. Then tap LOAD .CAL FILE to pick the calibration file that came with your mic. Phon Pro is required to load calibration files; without one, the external mic is used with its nominal sensitivity.
Measurement microphones ship with a per-unit calibration file, or the manufacturer offers it online by serial number. For the Dayton Audio iMM-6C, the serial is printed on the microphone and the file is downloaded from Dayton Audio's website. Save it in Files or iCloud Drive, or AirDrop it to your iPhone, then pick it from the app.
A plain text file in the common FRD layout: comment lines start with *, one of them giving the sensitivity at 1 kHz, followed by one frequency deviation pair per line. The extension does not matter: .cal, .frd and .txt all work.
*1000Hz -36.5 20 -1.2 25 -0.9 … 20000 2.1
A sample file with synthetic data is available for testing.
Phon Pro is a one-time purchase, with Family Sharing, that unlocks calibration file loading for external microphones, the C and Z frequency weightings, the Slow and Impulse time constants, the Leq column and CSV export. The free app measures with A-weighting and the Fast time constant.
Open the paywall by tapping any locked control and choose RESTORE PURCHASES. Make sure you are signed in to the App Store with the Apple Account that made the purchase, or one in the same Family Sharing group. If it still does not unlock, email us with the purchase date.
The equivalent continuous level: the constant level that would carry the same acoustic energy as the varying sound over the whole session. Phon integrates the energy of the frequency-weighted signal, so Leq does not depend on the Fast, Slow or Impulse setting. The AVG column, by contrast, is a plain average of the displayed decibel values.
A header of comment lines with the start time, device model, input, weightings, calibration applied and a summary, followed by one row every 100 ms:
elapsed_s,time,LAF,LAeq 0.00,2026-09-13T19:10:00.003+02:00,60.0,60.0 0.10,2026-09-13T19:10:00.103+02:00,61.0,60.5
Column names follow IEC 61672 notation: LAF is A-weighted, Fast; LCS is C-weighted, Slow; LZeq is Z-weighted Leq. Decimal points are always dots, so the file opens cleanly in Numbers, Excel and pandas.
Values measured with different weightings or time constants cannot be mixed, so changing either one starts a new measurement, as a physical sound level meter does. The live reading and the needle are not affected.
No. The audio is analysed on the device in real time and discarded. Nothing is recorded, stored or transmitted, and there are no analytics or ads. See the Privacy Policy.
Go to Settings › Privacy & Security › Microphone and enable Phon, then tap START again.